Cooper Lighting CMS185, CMS185W Landscape Lighting User Manual


 
How to operate your fixture
Step 1: Move slide switch on bottom of the sen-
sor to “TEST”. Set sensitivity knob to
medium (halfway) (L).
Step 2: Turn on the power to fixture. Allow fix-
ture to warm up approximately 40 sec-
onds before testing. (Lights will come on
and stay on during warm-up
period.)
Step 3: Aim sensor head toward desired detection area, maintaining a 15° down
angle to allow moisture to drain. NOTE: Maintain air spacing between
lamps and sensor head, at least 1”. Make sure sensor head is positioned
with control switches facing towards the ground.
Step 4: Walk across the detection zone at the farthest distance you wish your
detector to detect motion.
Step 5: Adjust sensitivity until you get desired results. Lights will turn off 4 sec-
onds after all motion stops.
Step 6: Move slide switch to 4 MIN or 12 MIN (AUTO mode). At dusk, lights will
operate in the AUTO setting.
How to select your desired feature
4
ENGLISH
THIS IS THE
BOTTOM SIDE
OF THE MOTION
DETECTOR
L
TEST
4 MIN
12 MIN
SENSITIVITY
Auto Setting
(motion activated)
Lights should turn on with
motion only at night and
should turn off after
4 or 12 minutes.
4 MIN
or
12 MIN
Keep the power to
the fixture on.
Dusk to Dawn Setting
(activated only at night)
Lights should stay on from
dusk to dawn and then reset
to the auto setting next
dawn.
4 MIN
or
12 MIN
Turn power on and off twice
within 3 seconds.
Standard Floodlight
Setting
Lights should stay on
continuously both day and
night (must be reset
manually).
TEST Turn power on and off twice
within 3 seconds.
Test Setting
Lights should turn on with
motion both day and night.
Lights should turn off after
4 seconds.
TEST Keep the power to the
fixture on.
Return to Auto Setting
(motion activated)
From any of the above
settings.
4 MIN
or
12 MIN
Turn the power “OFF” for at
least 40 seconds., then
back “ON”.
Mode of
operation:
Set slide switch
on sensor to:
How to set
power switch:
MS185,MS185W I.S. 325-1417 1/7/04 3:59 PM Page 4