Coleman 8fa3 Insect Control Equipment User Manual


 
6
Assembly cont.
Set tank in unit with open side
of Tank Ring facing front of
Mosquito Deleto.
Step 10
Set Tank Retainer on ring of
Propane Tank.
Step 11
Attach hose to tank.
Tighten thumb screw securely.
Leak Check
WARNING
Perform leak test outdoors.
Extinguish all open flames.
NEVER leak test when smoking.
Do not use the mosquito trap until connection has been leak tested
and does not leak.
Hose/Cylinder
Connection
Make 2-3 oz. of leak check
solution (one part liquid dish-
washing detergent and three
parts water).
Apply several drops of solution
at Hose/Cylinder Connection.
Turn Cylinder Valve ON.
If bubbles appear at connection,
there is a leak.
Turn Cylinder Valve OFF.
Disconnect, reconnect, and
perform another leak check. If
you continue to see bubbles
after several attempts, cylinder
valve or hose is defective and
should be replaced. Defective
cylinders should be returned to
cylinder’s place of purchase.
If NO bubbles appear at connec-
tion, the connection is secure.
Turn Cylinder Valve OFF.
Cylinder Valve
NOTE: Whenever gas connection
is loosened or removed, you
must perform a leak test.
Install Tank Cover.
Step 9
IMPORTANT: Be sure Tank Retainer is secure before moving the unit.
Unscrew Ignitor Button.
Insert one (1) AAA battery then replace Ignitor Button and tighten.
IMPORTANT: Make sure positive (+) end of battery is facing towards the
front of the unit as shown.
Step 12
Positive (+) end of
battery to the front
Open
side of
Tank
Ring
CAUTION
Do not tamper with the regulator or use any substitute regulator.