SPECIFICATIONS
VAC Electrical Specications 115 Volts @ 20 Amps Current Output
60 Hz
2200 Rated Watts / 2400 Max Watts
Two 120V, Household Receptacles with a 20 Amp circuit breaker
VDC Electrical Specications 12 VDC @ 10 Amps Current Output
Voltmeter Equipped 0-150 Volts / 50 Volt Increments
Display Lights Red (Run)
Generator Type Brush / Revolving Field / Self Exciting
Two Pole / Sincle Phase
Gasoline Engine 5.5 HP / Unleaded Gasoline Powered
Recoil Start / 4-Cycle / OHV Air Cooled
163 CC Displacement / 3600 RPM
0.63 Quart (0.6 Liter) Oil Capacity
EPA Certied
Fuel Tank Capacity 3.96 Gallons (15 Liters) / Includes Fuel Gauge
Estimated Run Time 11.8 Continuous Running Hours
Weight 103.6 Pounds
This product requires oil and fuel to be added before starting. Attempting to start the engine
without oil WILL ruin the engine and void the warranty.
The Emission Control System for this generator’s engine is warranted for standards set by
the U.S. Environmental Protection Agency and by the California Air Resources Board (also
known as CARB). For warranty information, refer to the back two pages of this manual.
SAVE THIS MANUAL
You will need this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures, parts list and assembly
diagram. Keep your invoice with this manual. Write the invoice number on the inside of the
front cover. Keep this manual and invoice in a safe and dry place for future reference.
REV 09h