SKU 92455 For technical questions, please call 1-800-444-3353. Page 17
abnormal noise or vibration occurs, have the problem corrected before further use.
Do not use damaged equipment.
Follow all maintenance procedures as outlined in the Engine Maintenance Sched-
ule below at the specified intervals. In addition, observe the following details:
Before each use: check to make sure the Engine’s oil level is adequate. If neces-
sary, fill the Engine’s Crankcase until the oil level is even with the Oil Fill Hole.
Before each use: with a soft brush, cloth, or vacuum, remove all debris from the
Generator and engine. Then, use a premium quality, lightweight machine oil to
lubricate all moving parts.
After the initial 20 hours of use and every 100 hours of use thereafter: drain
the old Engine oil and replace with approximately 3/4 (0.63) quart of a high quality
SAE 10W-30 grade engine oil.
Engine Maintenance Schedule
Interval
(More frequent maintenance
will be necessary in dusty or
severe conditions.)
8 hours or
daily, before
use
50 hours
or
weekly
100 hours
or
biweekly
200 hours
or
monthly
500 hours
or every 6
months
1000 hours
or
yearly
Details
Clean engine and
check bolts & nuts
Check and refill engine
oil
Change engine oil*
*Initial change immediately
after 20 hour break-in period
Clean spark plug (28A)
Clean and adjust spark
plug (28A) electrodes
Replace spark plug
(28A)
Clean air cleaner
element (19A)
Wear dust mask and vacuum or
blow clean with compressed air.
Replace air cleaner
element (19A)
Clean/replace fuel
filter(s)^
^QUALIFIED TECHNICIAN/
MECHANIC ONLY
Replace fuel lines and
filter(s)^
^QUALIFIED TECHNICIAN/
MECHANIC ONLY
Remove carbon from
cylinder head (11A)^
^QUALIFIED TECHNICIAN/
MECHANIC ONLY
Check and adjust valve
clearance^
^QUALIFIED TECHNICIAN/
MECHANIC ONLY
Clean and adjust
carburetor^
^QUALIFIED TECHNICIAN/
MECHANIC ONLY
Overhaul engine^
^QUALIFIED TECHNICIAN/
MECHANIC ONLY
Storage: Before storing, drain all fuel out of the generator’s gas tank. If this is not
followed, old fuel in the generator’s fuel tank may clog the generator and prevent it
from starting until cleaned out.