Chaney Instrument 06006RM/1036RX Weather Radio User Manual


 
7
Connect the larger end of the
USB cable into a USB port on
your computer.
USB functions on the display
unit are OFF by default. Verify
the display unit is powered on and receiving data from the outdoor sensor.
Next, set the USB mode on the display unit. Set to mode 3 for full PC
Connect functionality, or see page 5 for a description of all available
USB modes.
Select the SAME USB mode in the PC Connect software that you chose on
your display unit.
PC Connect is now ready for use. Please note that it may take up to
1 minute for the PC Connect software to begin receiving data from the
display unit.
4
5
6
(PC)
Specications
TEMPERATURE RANGE
Indoor: 32ºF to 122ºF; 0ºC to 50ºC
HUMIDITY RANGE
Indoor: 16% to 98%
WIND SPEED
0 to 99 mph; 0 to 159 kph
WIND DIRECTION INDICATORS
16 points
RAINFALL
0 to 99.99 in; 0 to 99.99cm
WIRELESS RANGE
330ft / 100m depending on home construction materials
OPERATING FREQUENCY
433 MHz
POWER
Display: 4.5V AC adapter
DATA REPORTING
Wind Speed: 18 second updates; Direction: 30 second updates
Outdoor temperature & humidity: 36 second updates
Indoor temperature & humidity: 60 second updates
PC Connect CSV Data Logging: 12 minute updates
PC Connect to AcuRite Software/App: 18 second updates
DISPLAY UNIT MEMORY
512 kilobytes (not expandable)
PC CONNECT SYSTEM
REQUIREMENTS
Windows® XP / Vista / 7 /8 and available USB port
High speed internet is required to use some advanced features
of PC Connect, such as the AcuRite software and app.
If your AcuRite product does not operate properly,
visit www.AcuRite.com or call (877) 221-1252 for assistance.
For more information, visit our Knowledge Base at http://www.AcuRite.com/kbase