Page 12 2008 Portable Spa Owner’s Manual
LTR20081000, Rev. D
Operating Your Spa
Light
Press the Light button to turn on the light. Press it once
again to turn the light off. All optional lighting such as
the control panel light and cabinet perimeter lighting is
controlled by the Light button and will turn on and off
with the spa light.
Option
Press the Option button to turn on the pump 2. Press it
once again to turn off the pump 2 (6200 Controls only).
6300 Controls - Pump 2 and Pump 3
Sequence
Press • Option button once to activate high speed
pump 2.
Press • Option button twice to activate high speed
pump 3 and high speed pump 2
Press 3 times to activate pump 3 hi speed only•
Press 4 times to turn pumps off•
Automatic Time outs
These features will automatically turn themselves off
during periods of continuous use:
Low speed pump After 4 hours•
High speed pumps After 15 minutes•
Optional circulation pump After 15 minutes•
Optional turbo After 15 minutes•
Spa light After 15 minutes•
Setting Filtration Cycles
Your spa is programmed to lter twice a day. The rst
cycle will begin 6 minutes after the spa is turned on and the
second cycle 12 hours later. The factory has programmed
the cycle to last for 2 hours but this can be switched to
4, 6, or 8 hours depending on your requirements. To
set ltration time, turn off the power to the spa at the
time of day you would like one of the ltration cycles to
begin then turn back on after 30 seconds. When power
has been restored, press the Temp button then the Jets
button. Press Temp button again to change the ltering
cycle duration. When desired duration is selected press
the Jets button to exit.
At the beginning of each ltering cycle the Turbo system
will run for approximately 30 seconds. The low speed
pump will run for the duration of the ltering cycle and if
an Ozone system is installed it will be activated. During
ltering, FC will appear on the main display.
Diagnostic Messages
Message Meaning
-- Spa temperature is unknown. After pump has been running for 2 minutes temperature will be
displayed.
HH Overheat protection (spa is shutdown) DO NOT ENTER THE WATER! One sensor has detected
118˚F (48˚C) at the heater. Remove the spa cover and allow spa to cool below 107˚F (42˚C).
Press any button on the topside display to reset spa. If spa will not reset after spa has cooled,
turn off power for approximately 30 seconds and then turn power back on. If display message is
repeated then shut the power off to the spa and call your dealer or service organization.
OH Overheat protection (spa is shutdown) DO NOT ENTER THE WATER! If the spa has reached
110˚F (43˚C), remove the spa cover to cool the water. At 107˚F (42˚C), the spa should reset
itself. If the spa does not reset, then shut the power off to the spa, wait 30 seconds and restore
power to spa. If display message is repeated then shut the power off to the spa and call your
dealer or service organization.
IC A possible ice condition exists within the spa. No action is required, the pump will automatically
activate.
SA or Sb Spa is shut down. Spa has detected that one of the sensors is not operating properly. One
of these may display briey during overheat then disappear when overheat situation has been
resolved. Call your dealer or service organization if message does not go away.
Sn Sensor (Spa is shut down). The high limit or water temperature sensors are not working correctly.
Call your dealer or service organization.