- 20 -
SERVICING INTERVALS
The periods recommended below are based on normal operating conditions. Severe or
unusual conditions may require more frequent lubrication or oil changes.
8 Hours or Daily; Telescoping Tubes and Quick Disconnect 20 Hours
1. Lubricate PTO driveline (7 locations).
ALERT: When using the safety chains supplied with the PTO shaft, the
shield bearings must be kept lubricated.
80 hours or once a season:
2. Lubricate rotor driven end
bearing (1 location)
3. Lubricate rotor drive end
bearing
(1 location).
4. Lubricate chain drive
bearing
(1 location)
- use 3 squirts only
- push grease in gradually