6200W Portable Generator
14
SPECIFICATIONS
Starting Wattage . . . . . . . . . . . . . . . . . .8,750 watts
Wattage . . . . . . . . . . . . . . . . . . . . . . . . .6,200 watts
AC Load Current:
At 120 Volts . . . . . . . . . . . . . . . . . . . . .51.6 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . .25.8 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity. . . . . . . . . . . . . . . 7 U.S. gallons
Shipping Weight. . . . . . . . . . . . . . . . . . . . . . 198 lbs.
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure
that all periodic maintenance tasks are completed on a
timely basis; that all discrepancies are corrected; and
that the unit is kept clean and properly stored. NEVER
operate a damaged or defective generator.
NOTE: Should you have questions about replacing
components on your BSPP generator, please call
1-800-743-4115 for assistance.
Engine Maintenance
See engine operator’s manual for instructions.
KEEP OUT OF REACH OF CHILDREN.
DON'T POLLUTE. CONSERVE
RESOURCES. RETURN USED OIL TO
COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit
clean and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with
snow, leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean
generator. Water can enter engine fuel system and
cause problems. In addition, if water enters generator
through cooling air slots, some of the water will be
retained in voids and cracks of the rotor and stator
winding insulation. Water and dirt buildup on the
generator internal windings will eventually decrease
the insulation resistance of these windings.
Battery Maintenance
Other than float charging, described elsewhere, no
maintenance is required for the starting battery. Keep
the battery and terminals clean and dry.
IMPORTANT: Battery charging should be performed in
a dry location, such as inside a garage.
Generator Cleaning
• Use a damp cloth to wipe exterior surfaces clean.
• Use a soft bristle brush to loosen caked on dirt or
oil.
• Use a vacuum cleaner to pick up loose dirt and
debris.
• Inspect cooling air slots and opening on generator.
These openings must be kept clean and
unobstructed.
• Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Thoroughly wash exposed areas with soap and water.
Avoid prolonged or repeated skin contact with used
motor oil.
CAUTION
• DO NOT expose generator to excessive moisture, dust,
dirt, or corrosive vapors.
• DO NOT insert any objects through cooling slots.
Improper treatment of generator can damage it and
shorten its life.
CAUTION
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
• Disconnect the spark plug wire from the spark plug and
place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Unintentional sparking can result in fire or
electric shock.
WARNING