Step 11 – Secure Gas Line
• Line up hole in Gas Clip with threaded hole in Support Plate.
• Attach using (1) Extra Long Screw.
• Tighten screw in Gas Line Clip until Gas Line is held securely in place.
Stand heater upright on base.
Caution:
Your Endless Summer™ Patio Heater
has been checked at all factory
connections for leaks. Recheck all
connections, as movement in shipping
can loosen connections. Check for
leaks even if your unit was assembled
for you at the store.
Step 12 – Check for Leaks
• Make 2-3 oz. of leak check solution by mixing one part liquid
dishwashing soap and three parts water.
• Turn cylinder valve ON.
• Check Gas Line / Control Valve for leaks:
Spoon several drops of solution onto Gas Line and Control Valve
connection.
• Inspect the solution at the connection to look for bubbles.
• If NO bubbles appear, then the connection is secure.
• If bubbles appear, there is a leak -
• Turn Cylinder valve OFF.
• Loosen screw on Clip.
• Release Gas Line fitting from control valve and re-attach making
sure connection is secure (see Step 9).
• Retighten Clip.
If you continue to see bubbles after several attempts, contact
1-800-762-1142 for assistance.
Check Gas Line / Cylinder valve for leaks:
• Turn cylinder valve ON.
• Spoon several drops of solution onto Gas Line and Cylinder valve
connection.
• Inspect the solution at the connection to look for bubbles.
• If NO bubbles appear, then the connection is secure.
• If bubbles appear, there is a leak:
• Turn Cylinder valve OFF.
• Release Gas Line fitting from Cylinder valve and re-attach making
sure connection is secure (see Step 13).
• If you continue to see bubbles after several attempts, contact
1-800-762-1142 for assistance.
• Turn Cylinder Valve OFF.