Aquacal HP7 Swimming Pool Heater User Manual


 
Connecting Controllers Not
Equipped With an OFF Setting (See application table within)
WARNING !!!! Dealer & Service Center Use Only
Appendix- B
HP-7 ….
Interfacing External Controllers
Not
Equipped with an OFF Setting
(Including, but not limited to, Double-Function Air Switches)
Compatible Applications
All Intermatic
”Air Force” Series
Controllers
All Air Touch
Controllers
Universal
Controller by
AquaCal
Pentair/Compool:
all “Easy Touch”
Series
WARNING !
DISCONNECT ALL ELECTRICAL POWER WHILE PERFORMING THIS WORK. FAILURE
TO FOLLOW THIS WARNING MAY RESULT IN SERIOUS INJURY OR DEATH.
CAUTION !
ONLY NON-ENERGIZING (“DRY”) CIRCUIT SHOULD BE CONNECTED; NEVER APPLY
EXTERNAL-SOURCE VOLTAGE TO THE HP7 MICROPROCESSOR TERMINAL BOARD.
FAILURE TO FOLLOW THESE INSTRUCTIONS WILL RESULT IN EQUIPMENT DAMAGE.
Connection Instructions (Uses the “FS-2” Connection on HP-7)
1. Connect two low voltage wires to the common (C) and spa connections (H) of
controller/air switch.
2. Wires should be cut long enough to reach from controller/air switch to the
heat pump electrical box interface.
3. Bring wires in to heaters electrical box on the low voltage side.
4. Interface these wires at power board, FS2 connections. (Female push-on
connectors should be used for wire hookup).
5. Third wire will not be needed from controller/air switch.
Programming & Activation at Microprocessor
1. Make sure pool water pump is on.
2. Power to unit will need to be on.
3. Hold both up and down arrows simultaneously for five or six seconds (touch
pad will display CF1).
4. Go to pool/spa switch, toggle until LOC appears.
5. Go to up arrow, go up to 50.
6. Go back to pool/spa switch, toggle until FS2 appears.
7. Go to up arrow, push twice. The number 1 should be displayed.
8. Step back for until display goes back to water temperature.
9. Controller is ready to test and use.
Customer and Technical Support 800-786-7751
22