2 3
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Install Batteries into Wireless Outdoor Sensor ....3
Installation of Wireless Module into
8910 Equipment Control Module................4
How to Link Wireless Outdoor Sensor ...........6
How to Mount the Wireless Outdoor Sensor ......8
Specifications..............................10
Error Codes................................10
Limited Warranty...........................11
FCC Declaration ............................12
IC Statement ..............................12
TABLE OF CONTENTS
FEATURES
In heat pump mode the Wireless Outdoor Sensor can be used to efficiently utilize an air source
heat pump.
•WhentheoutdoortemperatureislessthantheLowBalancePoint,theheatpumpwillbelockedoutandonly
auxiliaryheatingwillbeused.
•WhentheoutdoortemperatureishigherthantheHighBalancePoint,theauxiliaryheatingwillbelocked
outandonlyheatpumpwillbeusedtoprovideheating.
Indoor Air Quality functions can use the Wireless Outdoor Sensor.
•Controlhumidificationsetpointbasedonoutdoortemperaturetopreventcondensation.
•Lockouthumidificationfortemperaturesover60°Forbelow-30°F.
•Lockoutventilationbasedonhighand/orlowoutdoortemperatures.
•Displayoutdoortemperatureandhumidityonthermostat.
INSTALL BATTERIES INTO WIRELESS OUTDOOR SENSOR
1. RemovethecoverofWirelessOutdoor
Sensortoaccessbatterycompartment.
See Figure 1.
2. Install two fresh Lithium AA sized
batteries.Batteriesincluded.
3.Replacecover.
FIGURE 1
90-1788