American Standard 6060E SERIES Hot Tub User Manual


 
WIRE SELECTION GUIDE
752864-100 Rev. C
DRAIN CONNECTION AND SYSTEM TEST
Using recommended drain opening, connect whirlpool drain to waste line. Tighten all drain joints securely. Check the
pump couplings and make sure they are hand-tight. Clean the whirlpool and fill with water to a point 2" above the top of
the highest jet. Recheck the pump couplings and make certain that they are not leaking. (Although the pump couplings
are factory tightened and inspected, some loosening may have occured during transit.) Make sure the whirlpool is
connected to the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the
whirlpool is running.
Maximum distance from
fusebox to motor
The sizes shown on this
chart are recommendations
for copper conductors
only. Always follow
local and national
electrical codes
Motor
Hi Performance
Rating
2.1
50' 100'
115V Power Line
150' 200'
12 10 8 8
(5)
SPIC AND SPAN
®
IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE
POST INSTALLATION CLEAN-UP
Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue depressor.
Do not use wire brushes or any other metal implement on bath surface.
Post installation clean-up generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or
stains may be removed using granular Spic and Span
®
mixed with water.
Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.
HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES.
Abrasive cleaners must not be used since they will scratch and dull the surface. Dulled areas can be restored by rubbing
with a white automotive-type polishing compound and waxing with a liquid wax.
WARNING: Prior to operation, review the Important Safety Instructions listed in this instruction manual.
Once the heater is installed and the whirlpool pump is operating, the heater is totally automatic. The heater will help maintain the
temperature of the water in the bath.
Pressure Switch
The heater is equipped with a preset pressure switch. The pump must be running with water flowing in the whirlpool to allow the heater
to turn on.
Indicator Light
This light turns on whenever the heater is operating. See Fig. 2.
High-Limit Switch
The heater includes an exclusive "Intelligent High-Limit". This safety circuit will not "false trip" from hot tap water. It will only turn the
heater off if the thermostat fails. To reset, simply press the button. If the high-limit trips frequently, call a service technician.
OVERHEAT
PROTECTION
HEATER ON
RESET
E-Z INSTALL
WHIRLPOOL
HEATER
E-Z INSTALL WHIRLPOOL HEATER OPERATION
Fig. 2