8
Operating instructions
4. Refueling
Use clean heating oil or diesel fuel
WARNING! Using the wrong fuel can
be hazardous!
Capacity of tank: 4 gal.
Filling of fuel for the burner through the filler opening (4). Capacity of tank: 4 gal. Only use clean heating
oil, diesel fuel, or kerosene.
The fuel level can be read on the level indicator (5).
If the burner stops unintentionally, check the fuel level in the tank and if necessary, refill (at least 2 gal).
To protect the life of the fuel pump, it is important that the machine is not allowed to run without fuel in the
tank.
5. Spray handle - accessories
Clean quick-connect nipple each time
the spray lance has been detached.
Pull the grey quick coupler release (7) forward.
Insert the nipple of the spray lance (9) in the quick coupling and release #7.
Tug on the spray lance or other accessory to ensure it’s securely mounted, before starting the machhine.
6. Detergents - metering unit
Only use “normal” detergents.
Use of aggressive detergents may
damage equipment and affect the
environment.
Flush with clean water after use.
Detergents can be added under low pressure through the built-in metering system (10). Tip the cover (11)
out until it stops, and place a container in the holder. Drop the suction hose (12) and filter of the metering
unit into the container and close the cover/holder. Metering is infinitely variable (range 0-5), and the re-
quired dilution is achieved by turning the knob counter-clockwise, until the required step is against the
arrow on the control panel. Max. rate is approximately 5% (25:1). Once detergent application is completed
for the day, the system should be flushed through with clean water at Step 5, for approximately 1 min. The
knob should then be turned clockwise to Step 0.
7