Nilfisk-ALTO NEPTUNE 1 Pressure Washer User Manual


 
6
1)
Options / model variants
Original instruction
NEPTUNE 1, NEPTUNE 2
NEPTUNE 2 Special
3.6 Connecting the high
pressure hose
1. Put the quick connector of
the high pressure hose onto
the nipple on the cleaner.
1)
3.5 Fill up fuel tank
NOTE!
At temperatures below 8° C, the fuel
oil begins to solidify (paraffin precip-
itation). This can lead to difficulties
in starting the burner. Before the
winter period either add a solidifica-
tion point / flow improver (available
from the fuel oil trade) to the fuel or
use winter diesel fuel.
With the machine cold:
1. Pour fuel (fuel oil EL,
or Diesel oil DIN 51 603)
into the fuel tank.
The fuel must be free from con-
tamination.
Tank capacity see chapter 9.4
Technical data.
Be careful not to damage the
fuel tank filter to avoid dirt enter-
ing in the tank
3.7 Connecting the water
supply
1. Rinse the water supply hose
briefly in order to prevent
sand an other dirt particles
entering into the machine.
2. Connect water supply hose
to the machine.
3. Open water tap.
NOTE!
See chapter 9.4 Technical Data for
required quantity of water and water
pressure.
In the case of poor water quality
(sand, etc.), we recommend that a
fine water filter is fitted in the water
inlet.
We recommend the use of a textile-
reinforced water hose with a nomi-
nal diameter of min. 3/4" (19 mm).
3.4 Antiscale
The Nilfisk Alto Antiscale dosing
system is set by the factory.
To adjust the water hardness we
recommend that the inlet water
is tested accordingly.
Use the schematic to find the
right dosage of No Scale/anti
stone and water, and add the
mixture to the antiscale tank.
Machine flow L/h Pump size ml/h ˚dH ˚f ˚e Dosage
600 35 0-12 0-21,5 0 - 15 1:2 = 12ml/h
600 35 12-30 21,5 - 53,7 15 - 37,5 Pure = 35ml/h
700 35 0-12 0-21,5 0 - 15 1:1 = 17ml/h
700 35 12-30 21,5 - 53,7 15 - 37,5 Pure = 35ml/h
800 35 0-12 0-21,5 0 - 15 1:1 = 17ml/h
800 35 12-30 21,5 - 53,7 15 - 37,5 Pure = 35ml/h