1)
Options / model variants
Original instructions
NEPTUNE 5 FA
3.5 Fill up tank for Nilfisk-
ALTO AntiStone (Anti-
Scale)
1. Fill up Nilfi sk-ALTO Anti-Stone
(Anti-Scale)/water softener
reservoir with the sample
bottle provided. Nilfi sk-ALTO
AntiStone (Anti-Scale) pre-
vents any deposits of scale
and acts at the same time as
a corrosion inhibitor.
For compatibility reasons, use
only the tested Nilfisk-ALTO
AntiStone (Anti-Scale) which is
available as a six-pack of 1 liter
bottles by ordering part number
8466.
3.4 Fill up detergent tanks
1. Fill up detergent tanks (A) and
(B) with prediluted detergent.
Capacity see chapter 9.4
Technical Data
3.3 Install Crank handle
for high pressure hose
reel/cord reel
1. Pull cap of crank in arrow
direction.
2. Align tabs on crank with slot
in axle.
3. Put crank on axle of high pres-
sure hose reel/cord reel.
4. Fix crank by pushing the
cap.
A
B
3.6 Antiscale
The Nilfisk Alto Antiscale dosing
system is set by the factory.
To adjust the water hardness we
recommend that the inlet water
is tested accordingly.
Use the schematic to find the
right dosage of No Scale/anti
stone and water, and add the
mixture to the antiscale tank.
Machine flow L/h Pump size ml/h ˚dH ˚f ˚e Dosage
900 35 0-12 0-21,5 0 - 15 1:1 = 17ml/h
900 35 12-30 21,5 - 53,7 15 - 37,5 Pure = 35ml/h
1000 35 0-12 0-21,5 0 - 15 1:1 = 17ml/h
1000 35 12-30 21,5 - 53,7 15 - 37,5 Pure = 35ml/h