Nilfisk-ALTO 106269015 Pressure Washer User Manual


 
16
NEPTUNE PE
8 Troubleshooting
8.1 Indications on Display
Indication light Cause Remedy
Green LED
ON
> Appliance ready for operation.
When switching on, all the LEDs
light up once.
Yellow LED
ON
>
Fuel shortage Top up with fuel
Cold water operation possible
Red LED
flashing
> Service interval: Service due in
20 hours
Contact Nilfisk-Alto Service
Red LED
ON
> Service interval expired
Contact Nilfisk-Alto Service
Red LED
ON
>
>
Pump oil low
Engine oil low
Top up with pump oil
Top up with engine oil
Green LED
flashing
> Flow sensor failure
Contact Nilfisk-Alto Service
Cold water operation possible
> Water tap closed or water
shortage
Required volume flow and pres-
sure see chapter 9.4 Technical
Specifications
> Machine scaled
Contact Nilfisk-Alto Service
Green LED
and red LED
flash simultaneously
> Leakage or inadmissible opera-
ting condition by short-time
operation
After three times of short-time
ope ration the heating switches
off. Reset: Turn main switch to
position “OFF“, then start again.
Keep spray gun pressed for lon-
ger than 3 seconds. If a leak oc-
curs causing the machine to start
and stop briefly 3 times, then the
heating will switch off.
> Spray handle leaking
Check spray handle
> High pressure hose, coupling or
line system leaking
Replace high-pressure hose,
retighten screw fittings
> Water inlet filter dirty
Clean filter (see chapter 7.2.1)
>
High-pressure pump drawing in
air
Repair leaks
Cold water operation possible
Red LED
ON
>
Charging rate too low
Engine has not started
Generator defective
Contact Nilfisk-Alto Service
Red LED ON
>
Pump overheated
Let pump cool down, avoid long
by-pass time
>
Engine cooling water overheated
(Mitsubishi)
Check water level in radiator
Green LED and red
LED flash alternately
>
Overheating failure
Contact Nilfisk-Alto Service.
Operation with cold water pos-
sible.