2. Install transformer into hood canopy by lining up the 2 holes on the
flange of the transformer with the 2 screw studs in the top left side
of the hood canopy. Use 2 of the included 8-32 screws to make the
connection and fully tighten (Figure 1).
3. Attach the capacitor to the blower by lining up the two holes on the
flange of the capacitor with the holes on the blower. Use the 2 included
#6 screws to make the connection and fully tighten (Figure 2).
4. Lift blower up into the hood canopy and slide the keyhole slots in
the blower mounting flange over the two studs of the hood. Slide
the blower into place and tighten the hex nuts on the mounting stud
while lining up the 8 holes in the blower mounting flange to the 8
screw studs of the hood (Figure 3).
5. Using 8 of the included 8-32 screws and washers, mount the blower
in place and tighten all screws. Confirm that the blower is securely
seated in place and there are no air gaps around the blower gasket.
6. Plug the 3 wire quick connect cord from the blower into the receptacle
on the range hood canopy. Plug the 4 wire quick connect cord from
the blower into the receptacle on the transformer. Connect one end
of the wiring harness to the connector coming out of the transformer
and the other end to the receptacle in the range hood canopy. These
cords will only fit into the receptacles one way (Figure 4).
7. Reinstall the rear bottom plate by fitting the back edge of the plate
into the channel located on the back of the hood and reinstalling
the two screws and washers removed in
Step 1
(Figure 6).
SECTION 4
Finishing the Installation
1. Install the included fuse into the electrical panel by turning the fuse
cap counter clockwise and pulling out. Insert the included 1/4" x 1-1/4"
time delay fuse in the holder and reinstall into the panel (Figure 7).
NOTE: If you need to replace the fuse, replace with a 1/4" x 1-1/4" Bussman
MDA-10 or equivalent 10 amp, 250V ceramic, time delay fuse only.
2. Refer to the hood instruction manual to complete the installation,
for maintenance, and before restoring power.
3. The blower is covered under the range hood’s warranty.