2
2000 VA Output Capability
The 2000 VA Output Capability Option 019 is available on the following ac source model:
Agilent 6813B Option 019 AC Power Source (2000VA)
Option 019 increases the output VA capability of the standard Agilent 6813B AC Power Source from
1750 VA to 2000 VA. To achieve the increased output VA capability, the output rms voltage, dc voltage
and rms current ratings have increased slightly, to the maximum ratings documented in Table A-1. The
primary restriction that this increased output imposes on Option 019 units as compared to standard units,
is the reduction in the output frequecy range to between 45 and 100 Hz.
Specifications for Option 019
Table A-1 lists the specifications changes for units with Option 019. Performance specifications are
warranted over the ambient temperature range of 0 to 40
o
C. Unless otherwise noted, specifications are
for a sinewave with a resistive load at a frequency range of 45 Hz to 100 Hz, after a 30-minute warmup.
Table A-1. Performance Specifications
Parameter Agilent 6813B Option 019
Phases:
1
Maximum Output Ratings Power (VA):
2000 VA
dc Power (Watts):
1500 W
rms Voltage:
308 V
dc Voltage:
± 436 V
rms Current (in real-time mode):
16 A
dc Current:
10 A
Repetitive peak Current:
48 A
Non-repetitive peak Current
(inrush):
48 A
Crest Factor (current):
3 @16 A
(crest factor higher at lower
currents)
Output Frequency Range:
dc; 45 Hz100 Hz
Programming Accuracy
rms Voltage (45100 Hz):
0.15% + 0.3 V
(rms detection mode @ 25
o
C±5
o
C),
Frequency:
0.01% + 10 µHz
±(% of output+offset)
dc Voltage:
0.5% + 0.3 V
Measurement Accuracy
rms Voltage (45100 Hz):
0.03% + 100 mV
(@25
o
C ±5
o
C), ± (% of output +
offset)
Frequency:
0.01% + 0.01 Hz
dc Voltage:
0.03% + 150 mV
Table A-2. Supplemental Characteristics
Parameter Agilent 6813B (019)
ac Input Voltage Range (Vac):
191254 Vac
(230 Vac nominal)