
14
Hob
Rear left burner (semi-rapid) 2000 W
Front left burner (rapid) 3000 W
Rear right burner (semi-rapid) 2000 W
Front right burner (auxiliary) 1000 W
Oven
Electric Grill 1650 W
Gas Oven burner 2700 W
Oven light 25 W
Total Electric Rating 1675 W
Supply voltage (50 Hz) 230 V
Technical Data
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY
: II2H3+
APPLIANCE GAS SUPPLY: Natural Gas G20 20mbar
Dimensions
Height 900 mm
Depth 600 mm
Width 600 mm
Oven Capacity 56 litres / 1.97 Cu. ft
BURNER RAPID SEMI-RAPID AUXILIARY OVEN
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER (kW) 3.0 0.65 2.0 0.45 1.0 0.33 2.7 1.0
NOMINAL FLOW
RATE (m
3
/h) 0.286 0.062 0.190 0.043 0.095 0.031 0.257 0.095
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust. 114 Adjust.
1/100 mm
NOMINAL THERMAL
POWER (kW) 2.8 0.65 2.0 0.45 1.0 0.33 2.7 1.0
NOMINAL FLOW
RATE (g/h) 202 47 144 32 72 24 195 72
NOZZLE REFERENCE 86 40 71 32 50 28 83 52
1/100 mm
NATURAL
GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37
mbar
Instructions for the Installer
Important Safety Requirements
This appliance must be installed in accordance with
the Gas Safety (Installation and Use) Regulations
(current addition) and the I.E.E. Wiring Regulations.
Detailed recommendations are contained in the
following British Standard Codes of Practice - B.S. 6172,
B.S. 5440: Part 2 and B.S. 6891: Current Editions.
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S. 813
Current Editions and the ETCI Rules for Electrical
Installations.
Provision for Ventilation
The room containing the cooker should have an air
supply in accordance with B.S. 5440: Part 2: Current
Editions.
The following requirements for ventilation must be
met.
The cooker should not be installed in a bed sitting room
with a volume of less than 20m
3
, if it is installed in a room
of volume less 5m
3
an air vent of effective area of 110cm
2
is required; if it is installed in a room of volume between
5m
3
and 10m
3
, an air vent of effective area 50cm
2
is
required, while if the volume exceeds 11m
3
no air vent is
required. However, if the room has a door which opens
directly to the outside, no air vent is required even when
the volume is between 5m
3
and 11m
3
.
If there are other fuel burning appliances in the same
room, B.S. 5440: Part. 2: Current Editions should be
consulted to determine the requisite air vent
requirements.
For appliances installed in the Republic of Ireland
please refer to the NSAI- Domestic Gas Installation I.S.
813 Current Editions Table Four.
VALUE =
Hs 49.92 MJ/Kg
Ws 82.09 MJ/ m
3
VALUE =
Hs 37.78 MJ/m
3
Ws 50.72 MJ/ m
3