RO SYSTEM TROUBLE SHOOTING
PROBLEM REMEDY
General
High Product Water TDS
Membrane frozen, high temp, or backpressure. Replace membrane.
Membrane attack by chlorine Carbon pre-filter may be exhausted. Replace filter and membrane.
Product seal on end cap. Determine if seal or o-ring is bad. Replace as needed.
No Product Water or Not Enough Product Water
Feed water shut off. Turn on feed water.
Low feed pressure. Feed pressure must be at least 10 psi. Consider booster pump.
Pre-filter cartridge clogged. Replace pre-filter cartridge.
Membrane fouled. Determine and correct cause; replace or clean membrane.
Product check valve stuck. Clean or replace check valve.
Low pump discharge pressure
Low feed water temperature
Adjust reject valve or replace pump
Increase membrane feed pressure or heat the feed water.