Page 37HX760S
04 tEP
(
TEMP ADJUST
)
Function: Calibrating the Thermometer setting
Available Values: –9.9 ~ +9.9
Default: 0.0
See page 31 for details.
05 LP
(
LAMP MODE
)
Function: Selects the Lamp illumination method for the LCD/
Keypad.
Available Values: Cnt / kEY / off
Default: kEY
kEY: Illuminates the LCD/Keypad for 5 seconds when any key is pressed.
Cnt: Illuminates the LCD/Keypad continuously.
Off: Turns off the backlight for the LCD and keys.
06 dr
(
DIMMER
)
Function: Adjusting of the display brightness
Available Values: 00 / 01 / 02 / 03
Default: 02
07 SnL
(
SCAN LAMP
)
Function: Enable/Disable the automatic illumination of the
lamp when a signal is received on a channel during Scan-
ning
Available Values: on / oFF
Default: oFF
08 SCn
(
SCAN DISPLAY
)
Function: Selects the Scanning display mode
Available Values: nor (Normal) / SPL (Special)
Default: nor (Normal)
When this menu is set to “nor (Normal)”, the channel num-
bers during scan will be shown as scrolling on the display. When “SPL (Spe-
cial)” is selected the channel numbers on the display do not change unless a
call was received. The channel shown is the last channel that was received.
09 dt
(
DUAL WATCH MODE
)
Function: Selects dual or tri-watch as desired.
Available Values: d- (Dual Watch) / t- (Triple Watch)
Default: d- (Dual Watch)
See page 27 for details.