Symptom Probable Cause Corrective Action Recommended Tools
NO RPM
READING
600R, 600U
Control Panel
Defective Cables
Defective RPM
Sensor Set
Disconnect 5PA from 5PB. (Page 19-
20).
Set meter to check continuity between
pins 2 and 5 of 5PB
Turn crank and align the magnet with
the sensor
Is there continuity? If Yes – Replace
Control Panel. If No- continue to next
step.
--------
Check continuity of RPM Sensor, when
magnet is in alignment with the sensor
there should be continuity, when not
aligned- no continuity. If it does not
respond properly- replace the sensor.
Check gap on RPM Sensor
Perform a continuity check on all upper
and lower cables.
No continuity? – Replace defective
cable.
Continuity? – Replace RPM Sensor Set.
Multi-meter