![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/cb/bcbe8638-b079-47f6-bcd9-9da1ffb09ae0/bcbe8638-b079-47f6-bcd9-9da1ffb09ae0-bg4.png)
Conversion Kit
6
4)
To adjust the cooktop for LP gas or to return to Natural Gas use, refer to the tables here below.
Natural gas LP
Qt Injector Qr Qt Injector Qr by-pass
BTU Ø mm BTU BTU Ø mm BTU mm
Front Right 3400 0.90 1200 Front Right 3400 0.54 1200 0.32
Front Left 6200 1.20 1500 Front Left 6200 0.72 1500 0.35
Central 13000 1.75 4000 Central 13000 1.02 4000 0.63
Rear Right 6200 1.20 1500 Rear Right 6200 0.72 1500 0.38
Rear Left 6200 1.20 1500 Front Left 6200 0.72 1500 0.38
NOTE: Save the orifices removed from the appliance for future use.
5)
After carrying out the above adjustments, remount in reverse order to the instructions given in point “3”.
Caution: refit all flame caps in the same points from which they were removed. In fact, it is not possible to
change the flame cap positions. After refitting them, ensure that they are perfectly in place and that there
is no clearance between the cooktop and the flame caps.
WARNING
FIRE HAZARD
- Use a soapy solution to check for proper tightness.
- Never test for gas leaks with a match or other flames.
- Failure to follow this instruction can result in death or fire