25
The minimum space for ventilating should be prepared for the smooth heat exchange
of the refrigerator.
1. It should be structured for air to enter
from the intake hole and to exit from
the discharge hole.
2. The passage ¡ should be secured
when the passage ¨ is not secured.
3. 200cm
2
or more of the air ventilation
at ¨ and ¡ should be secured.
5. Installing the built-in refrigerator
Floor plan of furniture and the maximum opening of the door
Requirements for the furniture floor
- Floor:
We recommend to use T 20mm for securing the
hardness.
- Base:
Install the base for the floor not to be deformed
by the weight (200kg at maximum: product +
food + furniture door + opening/closing shock,
etc.).
- Parallelism:
If the level of the floor is not correct, it may cause
to deform the entire furniture or not to close the
door due to the weight of the product.
- Securely fix the side plate of the furniture at the wall or the adjacent furniture. Because the product is fixed
with the screws from the hinge to the side plate of the furniture, secure the side plate of the furniture at the
hinge by 30T or more. (Additionally, the rigid plate with 15T or more should be attached at the side plate
of the furniture for the refrigerator to install.) If the side plate is thin, the product may be easily shaken
when the screws directly touch the wall.
Caution