A SERVICE OF

logo

 
Technical Data


It is supplied set for group H natural gas. A conversion kit from NG to LP gas is packed with the hotplate.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : Base of the hotplate.
Country of Destination: GB/IE
Gas Electric
Natural Gas 20mbar 220 - 240V 50Hz
Butane 29mbar
Propane 37mbar
(See appliance data badge for test pressures)


1173mm

499mm

See ‘Positioning of Hotplate’

650mm

Gas: Electric
Rp 1/2 at rear right-hand side 220 - 240V 50Hz

 

Injector Injector
Wok burner
3.65kW
internal 80
3.5kW (255g/h)
internal 54
external 129 external 77
Large Burner
3.0kW 134 3.0kW (218g/h) 87
Medium Burners
1.7kW 109 1.7kW (124g/h) 68
Small Burner
1.0kW 75 1.0kW (73g/h) 51
Gas burner inputs based on Gross Calorific Value
Maximum total electrical load at 230V 50 W (approximate total)