Activated charcoal fi lter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
• The fi lter is not washable and cannot be regene-
rated. It must be replaced when led S1 fl ashes
or at least every 4 months. The alarm signal
will only light up when the extractor motor is
switched on.
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the
leds start to fl ash.
Replacing the Filter
• Remove the grease fi lters.
• Remove the saturated activated charcoal fi lters
as shown (A).
• Fit new fi lters (B).
• Replace the grease fi lters.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a
later date.
• Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power sup-
ply.
• Restore the connection by pressing and holding T1.
• Release the button. All fi ve LEDs are turned on
• Within 3 seconds press T1 until LEDs T1 and T4 fl ash in confi rmation:
LED fl ashes twice - Activated charcoal fi lter saturation alarm ENABLED
LED fl ashes once - Activated charcoal fi lter saturation alarm DISABLED
Lighting
LIGHT REPLACEMENT
50 W halogen light.
• Remove the 2 screws fi xing the light cover.
• Remove the lamp by gripping the protruding
part and turning to the left.
• Replace with a new lamp with the same cha-
racteristics, making sure that you insert the two
pins properly into their housings.
• Replace the cover and fi x it in position using
the two screws removed as above