RACK MOUNTING
The Endura workstation mounts into an industry-standard 19-inch equipment rack. The Endura workstation occupies two rack units
(8.9 cm or 3.5 inches) of vertical rack space. The hardware necessary to mount the Endura workstation into a rack is supplied with the unit.
The rack must meet the following requirements:
Rack standard: 19-inch EIA-310-D compliant (rear column required).
Rack column depth: 50.8 to 76.2 cm (20 to 30 inches).
Column mounting hole provisions: 10-32 UNF-2B threaded holes or square window holes on front and rear columns.
Door systems (optional): Front doors must have at least 5.1 cm (2 inches) between the Endura workstation front bezel and the inside of the
door. Rear doors may be used only on rack columns that are more than 66.0 cm (26 inches) deep.
NOTE: Figure 3 identifies each piece of hardware for this procedure.
To install the Endura workstation in a rack:
1. If chassis mounting brackets are not attached: Attach one mounting bracket (supplied) to each side of the Endura workstation. Use four
10-32 x 0.25-inch Phillips pan head screws (supplied) for each bracket. Attach the brackets so that the tapered ends are positioned toward
the rear of the Endura workstation (refer to Figure 5).
2. Remove the four rubber feet from the underside of the unit if they are attached. Save the rubber feet and screws for possible future use.
3. Attach one front-mount rail (supplied) to one rear-mount rail (supplied). Make sure the rails are mounted back to back, as shown in Figure 6.
Use three 8-32 x 0.375-inch Phillips truss head screws (supplied) in any of the available holes. Leave the screws loose; they will be
tightened later in the installation.
Figure 6. Assembling a Support Rail
4. Repeat the previous step for the other rail set.
5. If installing the unit into a square-hole rack: Insert 10 cage nuts (supplied) into the square-hole rack as shown in Figure 7.
WARNING: Slots and openings in the cabinet provide ventilation to prevent the unit from overheating. Do not block these openings.
Never place the unit near or over a radiator or heat register. When placing the unit in a built-in installation, such as a rack, be sure to
provide proper ventilation.
(3) SCREWS, 8-32 X 0.375
PHILLIPS TRUSS HEAD