CONNECTING PELCONET TO A CM9502 ASCII SERIAL PORT
Refer to Figure 44 and Figure 50. This configuration lets an operator view and control cameras from a PC using a web browser. (The
operator’s PC is not shown on the diagram.)
Figure 50. Using PelcoNet with CM9502 to Provide Remote Control
Video In Video Out
Audio Out
Audio In
COM1: RS232/485 10/100 Base-T
Ethernet
Power
100-250VAC50/60Hz 100mA
COM2: RS232
PELCONET TRANSMITTER
2
3
4
5
6
7
1
8
TX-
TX+
RX-
RX+
TRANSPARENT DATA PORT
VIDEO
USING INTERNET EXPLORER
SET TRANSPORT SETTINGS:
BAUD RATE
DATA BITS
PARITY
STOP BITS
9600
8
ODD
1
LOOPED
SERIAL
PORTS
MON 1
CM9502-KBD
CM9502
RJ-45 WALL
BLOCK &
STRAIGHT
CABLE
SUPPLIED
PELCONET CM9502 ASCII SERIAL PORT SETUP
TO NETWORK (LAN/WAN)