9
Major Operating Controls and Their Functions
■ Camera head
q Lens mount section
C-mount lens is mounted on this section. (☞ page 14)
w Camera cable connector
This connector is used to connect the camera cable
(option).
<Camera cable> (option)
GP-CA932/4, GP-CA932/4E (4 m {13.1 ft.})
GP-CA932/6, GP-CA932/6E (6 m {19.7 ft.})
e Tripod socket
The tripod socket hole is used when the camera head is
secured to the tripod.
The tripod socket can be mounted on either top or bot-
tom of the camera head.
Tripod socket hole: 1/4-20 UNC
Important:
• Be sure to turn off the power of the CCU before con-
necting or disconnecting the camera cable.
• Avoid bending excessively or breaking the camera
cable.
• Use the specific-camera head only.
r Power switch [DC POWER]
This switch toggles the power of the CCU and camera
head on and off. The switch lights green while the
power is turned on.
t Scene file selection button [SCENE]
The button selects a scene file from 1 to 3. Each scene
file should be set up beforehand using the SETUP
menu. (☞ page 20)
Selection of a scene file turns on the green LED of the
selected file number.
y Gain selection button [GAIN]
This button selects a gain from OFF, LOW, and HIGH.
Selection of a gain turns on the green LED of the select-
ed gain. No LED is turned on when the gain is set to off.
Selectable gain varies depending on the setting in the
SETUP menu (☞ page 19).
When GAIN is set to "AUTO" and SENS UP is set to
"OFF": The gain is always set to "HIGH".
u Freeze/menu button [FREEZE (MENU)]
Pressing this button: Displays the current image as a
static image when "FREEZE" in the SETUP menu is
set to "ON".
■ Camera control unit (CCU)
<Front>