A SERVICE OF

logo

34
WARNING
16. Disassembly and Assembly Instructions
High voltages are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding
with repair work. Failure to heed this caution may result in electric shocks.
16.1 Outdoor Unit Removal Procedure
Caution! When handling electronic controller, be careful of electrostatic discharge.
16.1.1 Removing the Cabinet Top Plate
1. Remove the cabinet top plate (remove the
11 screws).
Fig. 1
16.1.2 Remove the Control Board Cover and Particular Plates
2. Remove the control board cover (remove the
5 screws).
Fig. 2