Outdoor Unit : CU-4KE24NBU
Indoor Unit : CS-MKE9NKU × 3
Power Supply : 230V Single Phase 60Hz
< Cooling Capacity (Low Ambient) >
TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)
NOTE
RATING CAPACITY: 23,200 BTU/h AIR FLOW RATE: 777 CFM
INDOOR OUTDOOR
ENT. TEMP.
o
F (
o
C) AMBIENT TEMP.
o
F (
o
C)
WB DB 15 25 35 45 55
(-9.4) (-3.9) (1.7) (7.2) (12.8)
TC 23,390 23,310 23,350 23,510 23,420
72 (22.2) SHC 18,350 23,310 18,350 18,350 18,350
59 76 (24.4) SHC 20,910 23,310 20,910 21,070 21,070
(15.0) 80 (26.7) SHC 23,390 23,310 23,350 23,510 23,420
84 (28.9) SHC 23,390 23,310 23,350 23,510 23,420
88 (31.1) SHC 23,390 23,310 23,350 23,510 23,420
TC 23,620 23,610 23,770 24,080 24,070
72 (22.2) SHC 14,880 23,610 14,880 15,030 15,030
63 76 (24.4) SHC 17,600 23,610 17,600 17,750 17,750
(17.2) 80 (26.7) SHC 20,310 23,610 20,460 20,610 20,460
84 (28.9) SHC 23,030 23,610 23,030 23,180 23,180
88 (31.1) SHC 23,620 23,610 23,770 24,080 24,070
TC 23,660 23,750 24,060 24,550 24,640
72 (22.2) SHC 11,410 23,750 11,560 11,710 11,710
67 76 (24.4) SHC 13,970 23,750 14,280 14,430 14,430
(19.4) 80 (26.7) SHC 16,840 23,750 16,990 17,140 17,290
84 (28.9) SHC 19,560 23,750 19,710 19,860 19,860
88 (31.1) SHC 22,270 23,750 22,420 22,570 22,570
TC 23,470 23,680 24,180 24,870 25,100
72 (22.2) SHC 7,640 23,680 7,940 8,240 8,240
71 76 (24.4) SHC 10,350 23,680 10,660 10,810 10,960
(21.7) 80 (26.7) SHC 13,220 23,680 13,370 13,670 13,670
84 (28.9) SHC 15,780 23,680 16,090 16,390 16,390
88 (31.1) SHC 18,500 23,680 18,800 18,950 19,100
TC 23,050 23,390 24,090 25,020 25,390
75 76 (24.4) SHC 6,880 23,390 7,190 7,490 7,640
(23.9) 80 (26.7) SHC 9,600 23,390 9,900 10,200 10,350
84 (28.9) SHC 12,310 23,390 12,620 12,920 13,070
88 (31.1) SHC 15,030 23,390 15,330 15,630 15,780
1.
2. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Freeze Prevention Protection during cooling operation into account.
For this reason, the value may vary from the actual cooling characteristics.
58