3. WIRING
3-8
3.2.7 Wiring of the DC reactor connection terminals P/+, P1
These terminals are designed for connection of the power factor improving reactor (FR-BEL).
Remove the jumper across the terminals P/+-P1 and connect the DC reactor.
P1
FR-BEL
P/
+
Remove
umper.
NOTICE
The wiring distance (overall length) should be within 5m.
MEMO
Without removal of the jumper, the reactor will not be active.
3.2.8 Wiring of the brake resistor connection terminals P/+, PR
These terminals are designed for connection of the heavy-duty brake resistor.
1) Remove the screws in the terminals PR and PX and disconnect the jumper.
Terminal PX
Terminal PR
Jumper
2) Connect the brake resistor to the terminals P/+, PR.
FR-AX520-0.5K, 1.0K FR-AX520-1.5K to 3.5K
Terminal P/+
Terminal P
Terminal P
Terminal P/+
3) Change the Pr. 30 and Pr. 70 settings.
NOTICE
Always remove the jumper across the terminals PR-PX.