Parameter listParameter list
84
5
PARAMETERS
Parameter List
Automatic restart
functions
162
Automatic restart after instantaneous
power failure selection
0, 1, 10, 11 1 1 151 162 {{{{{
165
Stall prevention operation level for
restart
0 to 200% 0.1% 150% 151 165 { { { { {
— 168
Parameter for manufacturer setting. Do not set.
168
Parameter for manufacturer setting. Do not set.
— 169 169
Cumulative
monitor clear
170 Watt-hour meter clear 0, 10, 9999 1 9999 147 170 {{{× {
171 Operation hour meter clear 0, 9999 1 9999 147 171 { { { × ×
User
group
172
User group registered display/batch
clear
9999, (0 to 16) 1 0 167 172 {{{××
173 User group registration 0 to 999, 9999 1 9999 167 173 { { { × ×
174 User group clear 0 to 999, 9999 1 9999 167 174 {{{××
— 178
Parameter for manufacturer setting. Do not set.
178
Parameter for manufacturer setting. Do not set.
— 179 179
— 180 180
— 181 181
— 182 182
— 183 183
— 184 184
— 190 190
— 191 191
— 192 192
— 232 232
— 233 233
— 234 234
— 235 235
— 236 236
— 237 237
— 238 238
— 239 239
— 240 Soft-PWM operation selection 0, 1 1 1 163 240 { { { { {
— 241 Parameter for manufacturer setting. Do not set. 241 Parameter for manufacturer setting. Do not set.
— 244 Cooling fan operation selection 0, 1 1 1 176 244 { { { { {
Slip
compensation
245 Rated slip 0 to 50%, 9999 0.01% 9999 100 245 { × {{{
246 Slip compensation time constant 0.01 to 10s 0.01s 0.5s 100 246 { × { { {
247
Constant-power range slip
compensation selection
0, 9999 1 9999 100 247 { × {{{
— 249 Earth (ground) fault detection at start 0, 1 1 0 160 249 { { { { {
— 250 Stop selection
0 to 100s,
1000 to 1100s,
8888, 9999
0.1s 9999 138 250 {{{{{
— 251 Output phase loss protection selection 0, 1 1 1 160 251 { { { { {
Life diagnosis
255 Life alarm status display (0 to 15) 1 0 177 255 {{{××
256 Inrush current limit circuit life display (0 to 100%) 1% 100% 177 256 { { { × ×
257 Control circuit capacitor life display (0 to 100%) 1% 100% 177 257 {{{××
258 Main circuit capacitor life display (0 to 100%) 1% 100% 177 258 { { { × ×
259 Main circuit capacitor life measuring 0, 1 (2, 3, 8, 9) 1 0 177 259 {{{{{
Power
failure
stop
261 Power failure stop selection 0, 1, 2 1 0 156 261 { { { { {
— 267 Parameter for manufacturer setting. Do not set. 267 Parameter for manufacturer setting. Do not set.
— 268 Monitor decimal digits selection 0, 1, 9999 1 9999 147 268 { { { { {
— 269 Parameter for manufacturer setting. Do not set. 269 Parameter for manufacturer setting. Do not set.
— 270 Stop-on contact control selection 0, 1 1 0 139 270 × { { { {
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Control Mode-based
Correspondence Table
Parameter
Clear
All clear
V/F
V/F
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC