![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/20/d20c14ea-a1fa-404e-b670-d057fca56b65/d20c14ea-a1fa-404e-b670-d057fca56b65-bg64.png)
1 J51 (for connecting the SGPIO connector of the mini
SAS cable)
3 SAS connectors (top: SAS 3; bottom: SAS 2)
2 SAS connectors (top: SAS 1; bottom: SAS 0)
When connecting hard disk drives to the system board using the mini SAS cable, connect the mini SAS
connector
4 to the mini SAS connector on the backplane. Connect the four SAS connectors 6 , 7 , 8 , and
9 to the SAS connectors 0, 1, 2, and 3 on the system board. Then, connect the SGPIO connector 5 to
the J51 connector on the system board.
Notes:
• Remove any device that might prevent you from connecting the mini SAS cable to the system board.
• For the location of the mini-SAS signal cable connector on the backplane, refer to “Locating connectors
on the backplane” on page 18.
Figure 66. Mini SAS cable with four SAS connectors and one SGPIO connector
Note: The number on the label for each of the four SAS signal cables indicates the sequence when you are
connecting the cables to the corresponding SAS connectors (0-3) on the system board.
SAS connector SAS signal cable label System board SAS connector
6
P1
SAS connector 0
7
P2
SAS connector 1
8
P3
SAS connector 2
9
P4
SAS connector 3
Starting the Conguration Utility program
During the POST, when the message “Press Ctrl-C to start LSI Logic conguration Utility...” is displayed, press
Ctrl+C to enter the Conguration Utility main menu. Press Enter and the Adapter List window is displayed. In
this window, you can view the controller list, view the hard disk drive information, and congure RAID.
When working with this program, you must use the keyboard. The keys used to perform various tasks are
displayed at the bottom of each screen.
Table 26. Items in the Adapter List window
Item Description
Adapter
The SAS adapter(s) detected
PCI Bus The PCI bus number assigned to the adapter
Dev/Fnc The PCI device or function assigned to the adapter
88 ThinkServer User Guide