Troubleshooting
10-6
Offset occures. — Run [Drum Refresh]. 8-113
— Run [MC] and decrease the
adjustment value. Decrease the
adjustment value 1 level at a time
from the current value. If there is
no improvement after the value is
decreased by 1 level, decrease by
1 level again. If there is still no
improvement, return the setting to
the original value.
8-115
Part of the image is
periodically faint or
blurred.
— Run [MC] and decrease the
adjustment value. Decrease the
adjustment value 1 level at a time
from the current value. If there is
no improvement after the value is
decreased by 1 level, decrease by
1 level again. If there is still no
improvement, return the setting to
the original value.
8-115
Irregular horizontal
lines appear in the
image.
— Run [MC] and decrease the
adjustment value. Decrease the
adjustment value 1 level at a time
from the current value. If there is
no improvement after the value is
decreased by 1 level, decrease by
1 level again. If there is still no
improvement, return the setting to
the original value.
8-115
The altitude is 1500 m
or higher and irregular
horizontal white lines
appear in the image.
— Run [Altitude Adj.] and set the
adjustment value to [High 1]. If
there is no improvement when the
value is set to [High 1], set to [High
2].
8-114
The altitude is 1500 m
or higher and dots
appear in the image.
— Run [Altitude Adj.] and set the
adjustment value to [High 1]. If
there is no improvement when the
value is set to [High 1], set to [High
2].
8-114
Symptom Checkpoints Corrective Actions
Reference
Page