Electrical
Voltage
100VAC to 240VAC (+/- 10%)
Frequency
50/60Hz auto detected at power-up
Maximum load
16A 240VAC (EUR)
10A 240VAC (AUS/NZ)
3600W/240VAC Resistive
700W/240VAC Inductive/Capacitive
2000W/240VAC Bulbs/Low Voltage Halogen
Minimum load
N/A
Load type(s)
Resistive
Inductive/capacitive
Low voltage halogen
Hardwired remote control
N/A
Retains all settings without power
Yes, saved in non-volatile EEPROM
Standby power consumption
< 0.75 watts
Safety approved
CE, C-Tick
Certifications
EN 300 220-2, 301 489-3
AS/NZS 4268, CISPR 22
IEC 60669-2-1
All product specifications are subject to change.
Troubleshooting
Problem
Possible Cause
Solution
On/Off Module LED is not turning
on
On/Off Module is not
getting power
Make sure On/Off Module is not
plugged into a switched outlet that is
turned off
On/Off Module won’t add to a
scene as a controller or responder
On/Off Module or the
controller is plugged into a
power strip or AC line filter
Powerline signals can’t travel through
some power filters. Plug On/Off
Module or controller into an
unswitched wall outlet.
The INSTEON signal may
be too weak
Add additional INSTEON devices or
move around existing INSTEON
devices. All INSTEON devices act as
INSTEON network repeaters.
Large appliances, such as
refrigerators or air
conditioners, may be
producing electrical noise
on the powerline.