EQQD140E EQQD144I
EQQD140E THE JOBLOG RETURNED BY
EXITNAME
FOR
JOBNAME
JOBNUM
IN APPLICATION
APPL
IS
INCOMPLETE. FOLLOWING DATA NOT FOUND:
DDNAME1
,
DDNAME2
Explanation: A joblog-retrieval request has been issued to a tracker where DELAYEDEXIT or DELAYED is specified
for JOBLOGRETRIEVAL. The Catalog Management makes a basic validity check of what is passed back from the
joblog-retrieval exit. It will check for the existence of a jobcard (which is always part of the JESJCL sysout dataset)
and the IEF375I/IEF376I messages (which are always part of the JESYSMSG dataset). DDNAME(s) associated with
the missing data are displayed.
System action: This error message is written to the tracker message log, EQQMLOG. CM stops processing the
current joblog-retrieval request, and the joblog-retrieval status is set to Error in the Current Plan.
User response: Step-level restart this operation manually. Then contact your system programmer.
System programmer response: Verify that JES installation setup or the job does not suppress JESJCL and/or
JESYSMSG files from being created. Verify the logic of the joblog retrieval exit.
EQQD141E OPC/ESA COULD NOT RETRIEVE REQUIRED DATA FROM THE HISTORY DATABASE.
Explanation: OPC/ESA tried to access operation data in the DB2 history database but failed. The reason is
described in message EQQD142, which follows this message.
System action: Processing continues, but the required data is not passed to the caller.
User response: Contact your system programmer.
System programmer response: Check message EQQD142.
EQQD142I DB2TXT
Explanation: This message describes why TME 10 OPC could not access the DB2 history database. It contains
messages issued by the DB2 system.
System action: Processing continues.
User response: Contact your system programmer.
System programmer response: Review the messages issued by DB2 and take the action described in the DB2
documentation.
EQQD143I DB2 SYSTEM
DB2
HAS STOPPED. THE HISTORY FUNCTION IS NOT AVAILABLE
Explanation: OPC/ESA has discovered that the DB2 system has either stopped or abended. It cannot support
requests for data from the history database.
System action: Processing continues but the history function is not available.
User response: Contact your system programmer.
System programmer response: Restart the DB2 system that stopped or abended.
EQQD144I DB2 SYSTEM
DB2
IS AVAILABLE
Explanation: The DB2 system containing OPC/ESA history data is available.
System action: Processing continues.
User response: None.
System programmer response: None.
74 TME 10 OPC Messages and Codes