NOZZLE & NEEDLE
● Unscrew Adjustment Ring (9)
● Remove the Air Cap (8)
● Completely remove Adjustment Screw (4)
● Remove the Spring (3)
● Push out the Needle (2) – do not use tools for this
● Remove the Fluid Tip (7)
● Remove Air Flow Plate (6)
● Remove Nozzle Washer (17)
● Place all of these items into a container and clean
● them using a brush and clean thinners
● Clean the inside of the gun
● Thoroughly dry these parts before
● reassembling
● Grease the Fluid Needle Packing (13)
● Reassemble parts in reverse order.
● It is recommended fitting the fluid tip (7) prior to the
● needle
NEVER DISPOSE OF PAINTS OR SOLVENTS INTO
DRAINS. CONTACT YOUR LOCAL
COUNCIL TO ARRANGE COLLECTION OR FOR
DETAILS OF NEAREST REGISTERED DISPOSAL SITE.
19