![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/26/52665044-bee8-49bc-a434-ed3fb04b5af8/52665044-bee8-49bc-a434-ed3fb04b5af8-bg10.png)
16
Table 3 — Electrical Data-- 551C (cont)
VOLTAGE
RANGE
COMPRESSOR(each) OUTDOOR FAN
ELECTRIC HEAT POWER SUPPLY DISCONNECT SIZE
UNIT
SIZE
NOMINAL
V --- PH --- Hz
IFM
TYPE
CONV
OUTLET
Min Max QTY RLA LRA QTY FLA
IFM
FLA
CRHEATER
--- --- A00 or
B00
Actual kW{ FLA MCA MOCP** FLA LRA
NONE — — 13.9 20.0 14.0 92.0
006A00 5.5 7.2 13.9 20.0 14.0 92.0
008A00 10.6 13.8 20.5 25.0 19.0 92.0
NO 414 508 1 8.4 70.0 1 0.8 2.6
009A00 12.9 16.8 24.3 25.0 22.0 92.0
008,008 21.1 27.7 37.8 40.0 35.0 92.0
008,009 23.4 30.1 40.8 45 38 92
STD
NONE — — 16.6 20.0 16.0 94.0
006A00 5.5 7.2 16.6 20.0 16.0 95.0
008A00 10.6 13.8 23.9 25.0 21.0 95.0
ES 414 508 1 8.4 70.0 1 0.8 2.6
009A00 12.9 16.8 27.7 30.0 25.0 95.0
008,008 21.1 27.7 41.2 45.0 37.0 95.0
060
008,009 23.4 30.1 44.2 45 40 95
(tons)
460 --- 3--- 60
NONE — — 14.7 20.0 14.0 101.0
006A00 5.5 7.2 14.7 20.0 14.0 102.0
008A00 10.6 13.8 21.5 25.0 20.0 102.0
NO 414 508 1 8.4 70.0 1 0.8 3.4
009A00 12.9 16.8 25.3 30.0 23.0 102.0
008,008 21.1 27.7 38.8 40.0 36.0 102.0
008,009 23.4 30.1 41.8 45 38 102
HS
NONE — — 17.4 20.0 17.0 104.0
006A00 5.5 7.2 17.4 20.0 17.0 104.0
008A00 10.6 13.8 24.9 25.0 22.0 104.0
ES 414 508 1 8.4 70.0 1 0.8 3.4
009A00 12.9 16.8 28.7 30.0 26.0 104.0
008,008 21.1 27.7 42.2 45.0 38.0 104.0
008,009 23.4 30.1 45.2 50 41 104
NO
NONE — — 11.5 15 11 65
STD
YES
518 632 1 7.1 53.0 1 0.6 2.0
NONE — — 13.6 15 13 67
060
NO
NONE — — 12.3 15 12 74
(tons)
575 --- 3--- 60 HS
YES
518 632 1 7.1 53.0 1 0.6 2.8
NONE — — 14.4 20 14 76
Per fect
NO
NONE — — 12.2 15 12 78
Humimdity
YES
518 632 1 7.1 53.0 1 0.8 3.4
NONE — — 14.4 20 14 80
FLA ---Fu ll LoadAmps
HACR --- Heating,AirCon ditioningand Refrigeration
IFM --- Indoor(Evaporator)Fan Motor
LRA --- LockedRotorAmps
MCA --- MinimumCi rcuit Amps
MOCP --- Maxim um Overcurrent Protection
NEC --- National Electrical Code
OFM --- Outdoor(Condenser)Fan Motor
RLA ---RatedLoadAmps
NOTES:
* Thevalueslistedin thistabledonotincludepowerexhaust. Seepowerexhausttableforpowerexhaustrequirements.
**Fuse orHACR breaker
{ Heatercapacity(kW)is basedon heatervoltage of240v,480v or575v. If powerdistribution voltage to unit varies fromrated heatervoltage,heater kWwillvary accordingly