6. USING THE OPERATION PANEL AND FRONT PANEL
RH-9800
26
P4. Setting θ
2
correction
1. The setting range is from -3 to 3 in steps of 1.
* Set to a larger value if you would like to rotate the
eyelet seam clockwise (when seen from the
finished side, or the reverse side when sewing).
2. Press the “up” button (L) or the “down” button (K) to
set θ
2
correction value.
* When the setting value is changed, the value
displayed will start to flash.
3. Press the ENTER button (N) to accept the θ
2
correction setting.
* The display will stop flashing and will start
illuminating steadily.
1158Q 1159Q
(L)
(N)
(K)