5. USING THE OPERATION PANEL (BASIC OPERATIONS)
34
BAS-311H
5-2-3. Using the production counter
<Setting the counter value>
1
Change the mode to production counter setting
mode.
SPEED indicator illuminates
TEST indicator and COUNTER indicator flash
While pressing the TEST key, press the
key.
The 7 digits of the current counter value will be
displayed in the PROGRAM No. display and the menu
display.
2
Change the counter value.
Press the or key (1) to set the counter value.
• The counter value can be set from [000][0000] to
[999][9999].
• If you press the RESET key during setting mode, the
value will become [000][0000].
If the value is changed, the display will change to flashing.
3
Apply the changed parameter setting.
Press the ENTER key.
The value will be applied and the display will change to
illuminated.
If you press the TEST key without pressing the ENTER
key, you can cancel the parameter changes.
4
Ending setting mode
TEST indicator switches off
Press the TEST key.
<Production counter operation>
The production counter is always operating. (It operates even if the production counter display is not active.) If you press the SELECT key so
that the COUNTER indicator illuminates when memory switch No. 300 is ‘ON’, the current production counter value will be displayed in the
menu display instead of the lower thread counter value. (The SPEED indicator will also illuminate at this time.)
1. The counter is incremented by 1 each time one sewing
operation is complete. If the production counter display is
active, the number being displayed in the menu display (1)
will be incremented by 1.
* If you would like the digits to be displayed in all columns, use
the temporary display function described below.
* If you press the RESET key (2) for 2 seconds or more, the
counter value can be reset to [0000].
Temporary display function
While pressing the ENTER key, press the F1 key. The
production counter will be displayed as 7 digits while the
keys are being pressed.
While pressing the ENTER key, press the F2 key. The lower
thread counter will be displayed while the keys are being
pressed.
3080B 2430B
2414B
2404B
3082B
For example,
1,234,500.