![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/6e/36eaaf38-a971-4eee-9a29-451eccc4376a/36eaaf38-a971-4eee-9a29-451eccc4376a-bg72.png)
106
BAS-311E.311EL.326E.326EL
Chapter 7
#3
After a few
seconds
after the
R/W switch
is pressed,
an error
code
appears.
#4
The work
clamp does
not move
up and
down
when the
foot switch
is stepped
on.
Probable causes
1. With error code [E.40], a floppy
disk is not inserted.
2. With error code [E.41] or [E.4F],
the floppy disk is defective.
3. Panel circuit board defective
1. Foot switch and code defective
2. Any cord in the control box is
defective.
3. Fuse blown
Check/repair/adjust
• When a floppy disk is inserted into the FDD, check
the sound of the motor.
• When error code [E.40], [E.41], or [E.4F] appears,
insert other floppy disk into the FDD.
If the FDD reads the floppy disk, the original disk
is defective.
(Make sure that the power is turned off.)
• Remove the connector for foot switch connected
to the outside of the control box, and check the
continuity between pins 1 and 2, and pins 7 and 8
in the connector on the cord. (For pneumatic
specification, check the continuity between pins 3
and 4.)
The continuity in each case should be normally
or 0 when the switch is stepped on.
• Insert the connector checked above, open the
control box, and check the continuity between
pins 1 and 2, pins 3 and 4, pins 5 and 6 in
connector P19 (FOOT) on the PCB.
(Without removing the connector, put a tester
from the lead side.)
The continuity in each case should be normally
or 0 when the switch is stepped on.
• Remove fuse no.1 and check the continuity.
(If there is no continuity, go to the next item.)
Parts to be replaced
Drive device
Floppy
Panel circuit
board
Foot switch
Foot switch code
assembly
(Quick melting
type 5A-250V
Error status
1 - 2 Presser foot
Connector on the cord
7 - 8 Start
3 - 4 Second switch Presser
(Pneumatic only)
Presser
foot
Start Second switch
Presser
(Pneumatic only)