INSTALLATION INSTRUCTIONS (continued)
NOTE: This equipment must
be installed in compliance with
all applicable federal, state
and local plumbing codes and
ordinances.
WARNING:
SHOCK HAZARD
Brewer must be properly
grounded to prevent possible
shock hazard. DO NOT assume
a plumbing line will provide
such a ground. Electrical shock
will cause death or serious
injury.
IMPORTANT: Do not connect
brewer to electrical power until
the tank is lled with water.
Pour water into the pour-over
opening until water ows from
the brew head.
IMPORTANT:
Supply power must match
nameplate for voltage and
phase. Connecting to the
wrong voltage will damage the
brewer or result in decreased
performance. Such damage is
not covered by warranty.
In some areas, local codes require a backow preventer (check
valve) to be installed on the inlet water line. If a backow
preventer is used, you must install a water hammer arrester
in the incoming line, between the backow preventer and the
brewer inlet, as far away from the brewer as space will allow
.
This will relieve the excessive back pressures that can cause
faucet leaks and solenoid malfunctions.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT: Before connecting to electricity, make sure
automatic brewers are connected to the water supply.
Models 8778, 8780, 8782, 8783 & 8785 (120V units) are
equipped with a cord and plug. They require a 115 - 125 volt
15 amp circuit (50/60 Hz, 2 wire plus ground, with NEMA 5-15R
receptacle).
IMPORTANT: The ground prong of the plug is part of a system
designed to protect you from electrical shock in the event of
internal damage. Never cut off the ground prong nor twist a
blade to t an existing receptacle. Contact a licensed electrician
to install the proper circuit and receptacle.
Models 8786 & 8788 must be wired by an electrician, and
require a 115/230V 20A circuit (50/60 Hz, 2 hot legs / 1 neutral
leg, plus ground). Remove front panel to gain access to terminal
block. Green terminal must be connected to a suitable building
ground. Circuit must be capable of 3500 Watts.
See gure 3 at right.
IMPORTANT: Wiring must be installed in approved solid or
exible conduit, and must be secured to the brewer with a strain
relief (to be provided by the installer).
Fig. 3 115/240 Volt Terminal Block
5
Fig. 2 Water Supply Installation
COPPER LOOPS OR
FLEX LINES
(PROVIDED BY
PLUMBER)
SHUT-OFF VALVE
(PROVIDED BY
PLUMBER)
FLOW
WATER
SUPPLY
WATER INLET
FITTING
SOLENOID
STRAINER
WASHER
IL1615
WARNING
622 2M-75854 Owners Manual Gourmet 1000 Airpot/Thermal