17
4. Bleed the air from the filter tank by
turning the small black knob on the
top of the filter tank counterclockwise.
Allow the filter tank to bleed for
approximately one minute, or until
water drips from the fitting. Turn the
fitting clock-wise to close the bleed
valve.
Plug the spa into a properly grounded electrical outlet.
5. P
lug the power pack into the electrical outlet. e water pump will
turn on and begin pumping water. Water should flow from the
small return nozzle on the bottom inside wall of the spa behind the
power pack. If water is not flowing from the return nozzle, repeat
the air bleeding instructions provided in step 4. Unplug the power
pack while bleeding air.
NOTE: If the air is not properly bled from the filter tank,
the water pump will be air bound and no water will
flow. This will prevent the spa from heating, and
the water will not be filtered. Make sure water is
flowing from the return nozzle before continuing.
6. Place the inflatable
bladder cover on the spa.
Make sure the cover is
centered on the spa.