– 18 –
741-061
741-066
w
q
762-004
830-002a
e
q
762-005
AE00241
GROUND (Earth)
Make sure to ground (earth) the generator.
Check "SAFETY INFORMATION" on page 7.
å EF4000DE/YG4000D
∫ EF5200DE/EF6600DE/YG5200D/YG6600D/YG6600DE
AE00231
BATTERY
(for EF4000DE/EF5200DE/EF6600DE/YG6600DE)
(See page 34 for more details)
Check the fluid level and fill if necessary.
Use only distilled water if refilling is necessary.
Installation
1. Turn the engine switch to the "STOP" position to
prevent accidental short circuiting.
2. Install the battery on the battery mount tray
securely.
NOTE:
Clamp the red wire to the positive (+) terminal first,
then the black wire to the negative (–) terminal of the
battery. Do not reverse these positions.
w
Be sure to service battery leads to prevent arcing
when the battery is not installed.
9 Disconnect the battery charging output lead.
Then insulate the generator side connector by
folding it back on itself and carefully wraping it
with electrical tape to prevent electrical con-
tact with ground (earth) or any other leads.
9 Remove the battery leads from the generator.
1 Connector
2 Battery leads
3 Electrical tape
A
B
7WV-9-11 A 10/16/03 1:29 PM Page 18