APPLICATION RANGE
AC
Power factor 1 0.80.95
0.40.75
(Efficiency 0.85)
EF4000DE/YG4000D 3,500W 2,800W 1,190W
EF5200DE/YG5200D 4,500W 3,600W 1,530W
EF6600DE
YG6600D 6,000W 4,800W 2,040W
YG6600DE
NOTE:
9 “–” means below.
9 Application wattage indicates when each device is used by itself.
cC
Be sure the total load is within generator rated output otherwise generator dam-
age will occur.
NOTE:
Some precision equipment is voltage sensitive and may require a more uniform voltage
supply than portable generators provide. Examples include some medical equipment,
personal computers, and some inverters that sense peak and RMS voltage values.
Consult the precision-equipment vendor before relying on any portable generator to pro-
vide power to such equipment.