Vector 1000 WATT Portable Generator User Manual


 
17
Appendix A – Battery Installation
In most cases, the seald lead-acid battery is installed by the user. The battery
is easily installed using the provided hardware. The user will need a medium
Phillips head screwdriver and a wrench to do the battery installation.
CAUTION: MAKE SURE THE RED (POSITIVE) CABLE CONNECTS TO THE
POS (+) BATTERY TERMINAL AND THE BLACK (NEGATIVE) CABLE
CONNECTS TO THE NEG (–) TERMINAL.
Reverse connections will cause damage and void the warranty.
NOTE: The inverter is attached to the battery compartment cover. The inverter
is not separated from the cover during battery installation. The battery
compartment cover is removed by unscrewing (counterclock-wise) two
Phillips head screws located on the left and right forward corners of the
cover. The two inverter terminal covers (red and black) are unsrcewed
(counterclock-wise) and lifted off. (See Figures A1 and A2) Remove the
lock washer on each terminal. The entire inverter and battery
compartment cover are carefully lifted and placed on a flat stable
surface. The battery compartment should contain the battery clamp
adapter cable and the universal terminal adapter. Remove any items from
the battery compartment. Lift the two cables out of the way so they are
not down inside the battery compartment. Carefully lower the battery into
the battery compartment. The terminals on the battery can be one of
several types. The user should take the supplied universal connector and
configure it to adapt the cable ends to the battery posts. Make sure all
connections are mechanically tight. Replace the inverter and battery
compartment cover. Replace the two Phillips screws and the lock washers
and terminal covers. Make sure the red and black covers are on the
correct terminals.
11. Specifications:
Jump-Start Clamps ..................................................... 400 Amps - Heavy Duty Copper
Jumper Cables ........................................................................... 9mm
2
Welding Cable
Battery .................................. User-Supplied 12 Volt, Group 27 size. Sealed Lead-Acid
Flourescent Lamp..................................................................... 8 Watt Fluorescent Tube
Dual Accessory Socket Protection ................................... 30 Amp Self-Resetting Breaker
Power Inverter ........ 1000 Watt,15 minutes, 800 watt continuous, 60 Hz, 110-120 VAC
Power Inverter Momentary Peak................................................................. 2000 Watts
Inverter Waveform........................................................................ Modified Sine Wave
Inverter DC Input Range................................................................... 10.0 to 15.5 VDC
Inverter Low Battery Audible Alarm .............................................................. 10.6 VDC
Automatic Shutdown . ..................................Low Voltage, Overload, Over Temperature
Compressor .............................................................................. Max Pressure, 300 PSI
Pressure Gauge Type ................................................................................ Analog Dial
Air Delivery ...................................................................................................9kg /cm
Operating temp.................................................................................-20° C to +80° C
Motor current .................................................................................................. 9 Amps
Dimensions ..................................... 20”H x 20”W x 18”D (50.8cm x 50.5cm x 45.72)
Weight .......................................................................30 lbs without battery (11.2 Kg)