Uniden GH 300 Lawn Mower Accessory User Manual


 
Hydraulic Motor Rebuild
14 311797B
Hydraulic Motor Rebuild
(Figure 5)
Removal
1. Relieve pressure, page 7.
2. Place drip pan or rags under sprayer to catch hydraulic oil
that leaks out during repair.
3. GH130 Models:
- Follow Steps 2-5 of pump removal instructions, page 17.
GH200, GH230, GH300 Models:
- Follow Steps 4-8 of pump removal instructions, page 18.
4. Remove hydraulic lines (271, 288) from fittings (266) at top
left and right side of hydraulic motor.
5. Loosen jam nut (264).
6. Unscrew and remove hydraulic motor cap (265).
7. Slide piston rod/hydraulic motor cap assembly (A) from
hydraulic motor cylinder (263).
8. Remove yoke (257).
a. Clamp hydraulic motor cap (265) in vise with hydraulic
motor piston rod facing up.
b. Use shortened Allen wrench to remove two screws
(260) from spring retainer (261). Remove yoke, spring
retainer, piston and trip rod assembly from hydraulic
motor cap.
9. Cover spring retainer (261) with a rag to contain detent
spring (258) and balls (259) when they are removed from
yoke. Remove detent balls and spring. Remove spring
retainer.
10.Put yoke in vise and remove piston rod assembly from
yoke.
Installation
1. Put hydraulic motor cap (265) in vise.
2. Install yoke (257), spring retainer (261), piston and trip rod
assembly in hydraulic motor cap (265). Use shortened Allen
wrench to install two screws (260) in spring retainer to
secure piston rod assembly to hydraulic motor cap.
3. Slide piston rod assembly into hydraulic motor
cylinder (263).
4. Screw down hydraulic motor cap (265). Unscrew hydraulic
motor cap until inlet and outlet align with hydraulic line
fittings and test hole in hydraulic motor cap points toward
belt guard (117).
5. Torque jam nut (264) against hydraulic motor cap (265) to
150 ft-lb (17 N·m).
6. Fig. 5. Install hydraulic lines (271, 288) to fittings (266) to
top left and right side of hydraulic motor; torque to 40 ft-lb
(54.2 N·m).
7. GH130 Models:
- Follow Step 2 of pump installation instructions, page 17.
GH200, GH230, GH300 Models:
- Follow Steps 2-7 of pump installation instructions, page
19.
8. Start engine and operate pump for 30 seconds. Turn engine
OFF. Check hydraulic oil level and fill with Graco hydraulic
oil, page 6.
FLYING PARTS HAZARD
Detent spring has high energy potential. If detent
spring is released without due care detent spring and
balls could fly into the eyes of the disassembler.
Wear safety glasses when removing or installing
detent spring and balls. Failure to wear safety
glasses when removing detent spring could result in
eye injury or blindness.
FLYING PARTS HAZARD