Test-Um TG200 Portable Generator User Manual


 
--3--
INSTRUCTIONS FOR USE
To Check the Status of a Phone Circuit
1) Move slide switch on left side of Turbo Tone
to the
STATUS position.
2) Connect black lead to TIP and the red lead to RING
or one
lead to each wire of the pair if designation is unknown.
• If
NRM lights up, it means the polarity is correct and the
black lead is connected to TIP.
• If the
REV lights, then the leads are reversed.
• If the
NRM or REV LED is bright, the line is not in use.
• If the LED is dim, the circuit is in use.
• If both
NRM and REV are on or flashing, an AC voltage
is present.
Application Hints: The TIP signal is nominally at ground potential.
Attaching the black lead to a ground point and connecting the
red lead to each wire of the pair can identify the RING line. When
the red lead is connected to RING, the
NRM LED will light.
The status LEDs also indicate a ringing line by both
NRM and
REV LEDs flashing brightly. To verify a phone line, connect the
Turbo Tone
in STATUS mode to the line to be tested and call
that line’s number from another line. The Turbo Tone
status
LEDs should indicate a ringing line.
To Check Continuity of a Circuit
Use only on non-energized circuits. Any energy present may
damage the Turbo Tone
or cause erroneous results. Turn off
tone if necessary.
1) Move slide switch on left side of Turbo Tone
to the
CONT position.
2) Connect one lead of Turbo Tone
to each end of the circuit
to be tested. If the DC resistance of the path is approximately
11,000 ohms or less, the
REV LED will light.
--2--
Note: The RJ jumper cable that has been provided with the
Turbo Tone
uses a unique colored modular connector
that can be plugged into a RJ11 jack or a RJ45 jack
without damaging either. Thereby allowing CAT 5 output
points to be accessed without using an adapter.
Warning!
Do not attach to live AC circuits. This could cause an extreme
shock hazard and damage the Turbo Tone
. Attachment to an
unknown circuit should always be in
STATUS mode.
--1--
FEATURES
• Four tone amplitude levels—
normal and half plus TURBO normal and half
• Half amplitude is
unbalanced for stronger
signal on twisted pairs
• Three distinctly different tones selected
from front panel
Constant Amplitude Signal over life of battery
for 100% signal strength all the time
Auto-off—tone turns off after 3 hours—
no dead battery if left on
• Tone may be added in any mode—
allows phone sets without monitor feature
to pick up tone
• No power draw in continuity mode with leads open—
no dead battery if left in continuity
• RJ jack allows use of modular cable without adapters
TG200
Part No.
TONE GENERATOR
Operating Instructions
Turbo Tone
TG200 Page 1