Sterling Plumbing 76111120 Hot Tub User Manual


 
Technical Information
Fixture*: basin area top area
Bathing well 40 (101.6 cm) x
27 (68.6 cm)
52 (132.1 cm) x
35 (88.9 cm)
To overflow water depth capacity
11 (27.9 cm) 55 gal (208.2 L)
* Approximate measurements for comparison only.
Pump: Hp V Hz A
1-speed 1.25 120 60 7
Model Door maximum
width
Door maximum
height
76111110
76111120
58 (147.3 cm)* NA*
* Varies with alternative walls.
Required Electrical Service
Dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump 120 V, 15 A, 60 Hz
Installation Notes
Install this product according to the installation guide.
Pump is supplied with a grounding type plug-in cord. Locate
the outlet behind the whirlpool, and within 24 (61 cm) of the
pump.
Do not disassemble the pump or piping as this could void the
warranty.
Size the drain cutout to fit the drain assembly that will be
used.
Stud positioning is critical.
Studs should be positioned roughly as shown for support clip
or roofing nail installation.
3" (7.6 cm)
60" (152.4 cm)
16" (40.6 cm)
19"
(48.3 cm)
43-1/2"
(110.5 cm)
43-1/2"
(110.5 cm)
42"
(106.7 cm)
3-1/2" (8.9 cm)
4"
(10.2 cm)
8-3/4"
(22.2 cm)
17-1/4"
(43.8 cm)
8-3/4"
(22.2 cm)
8"
(20.3 cm)
24-1/2"
(62.2 cm)
16" (40.6 cm)
14"
(35.6 cm)
6" (15.2 cm)
(Typical)
Pump Motor
Location
30" (76.2 cm)
Recommended Support
Clip or Roofing Nail
Location (5 total)
20"
(50.8 cm)
Drain Cutout
60" (152.4 cm) Min
60-1/8" (152.7 cm) Max
76111100
3-1/8" (7.9 cm)
Overflow
Detail
1-1/2"
(3.8 cm)
2" (5.1 cm) D. Drain
Product Diagram
ENSEMBLETM
ENSEMBLETM 42 (106.7 cm) BATH WHIRLPOOL
Page2of2
1021378-4-
E